EasyManua.ls Logo

Siemens SINUMERIK 840D sl - 23.5 View of the program blocks

Siemens SINUMERIK 840D sl
1002 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Overview of Alarms 08/2005
2-906
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
- NC Stop on alarm.
Remedy: Carry out new start-up with power section selection or enter the following data:
Operation of a power section with an FDD motor requires:
MD_1178 $MD_INVERTER_DERATING_SYN (derating factor at 8kHz)
Operation of a power section with an MSD motor requires:
MD_1179 $MD_INVERTER_DERATING_ASYN (derating factor at 8kHz)
Operation of a power section with a PE MSD motor requires:
MD_1179 $MD_INVERTER_DERATING_ASYN (derating factor at 8kHz)
MD_1175 $MD_INVERTER_THERM_CURR_ASYN (limit current power section for PE
MSD)
MD_1177 $MD_INVERTER_RATED_CURR_ASYN (limit current power section for PE
MSD).
Program Con-
tinuation:
Switch control OFF - ON.
310505 Axis %1 drive %2 measuring circuit error of absolute track, code %3
Parameters: %1 = NC axis number
%2 = Drive number
%3 = Fine error coding
Definitions: Absolute encoder (EQN 1325) Monitoring of the encoder hardware and the EnDat inter-
face
More accurate diagnostics via MD5023: $MD_ENC_ABS_DIAGNOSIS_MOTOR (diag-
nostics for absolute track on motor measuring system).
Bit nos. and their meaning:
Bit 0 Lighting failed
Bit 1 Signal amplitude too small
Bit 2 Code connection error
Bit 3 Overvoltage
Bit 4 Undervoltage
Bit 5 Overcurrent
Bit 6 Battery change necessary
Bit 7 CRC error (evaluate bit 13), note: see below
Bit 8 Encoder cannot be used, assignment of absolute track to incremental track not
allowed
Bit 9 C/D track for ERN 1387 encoder incorrect or EQN encoder connected
Bit 10 Log cannot be aborted
Bit 11 SSI level detected in data cable
Bit 12 TIMEOUT while reading measured value
Bit 13 CRC error (evaluate bit 7), note: see below
Bit 14 (810D) Wrong IPU submodule for direct measuring system
Bit 15 Encoder defective
CRC error: CRC error bit 7 and bit 13, meaning:
Bit 7: 0, bit 13: 1 CRC error from SIDA-ASIC
Bit 7:1, bit 13: 0 Control check byte error
Bit 7: 1, bit 13: 1 Error on correction of absolute track by incremental track
Bits 12 and 15: Zero level monitoring SSI
Bits 14 and 15: Idle level monitoring SSI
Reactions: - Mode group not ready.
- The NC switches to follow-up mode.
- Channel not ready.

Other manuals for Siemens SINUMERIK 840D sl