EasyManua.ls Logo

Siemens SINUMERIK 840D sl - Page 922

Siemens SINUMERIK 840D sl
1002 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Overview of Alarms 08/2005
2-922
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Positive quadrant: (MD 5481 + MD 5482) > (MD 5465 - 5466)
Negative quadrant: (MD 5484 + MD 5482) > (MD 5468 - 5466)
Enter a valid combination in the above drive MD.
Program Con-
tinuation:
Clear alarm with the RESET key in all channels. Restart part program.
310775 Axis %1 drive %2 knee area and saturation area of valve characteristic overlap
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: The knee area and the saturation area of the valve characteristic overlap.
Reactions: - NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Remedy: The knee area and the saturation area overlap if:
Positive quadrant: (MD 5465 + MD 5466) > MD 5486
Negative quadrant: (MD 5468 + MD 5466) > MD 5488
Enter a valid combination in the above drive MD.
Program Con-
tinuation:
Clear alarm with the RESET key in all channels. Restart part program.
311710 Axis %1 drive %2 resolution SSI motor measuring system invalid
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: The configuration of the motor measuring system for an SSI encoder is incorrect:
MD_5022 $MD_ENC_ABS_RESOL_MOTOR must not be 0.
Reactions: - Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Set MD_5022 $MD_ENC_ABS_RESOL_MOTOR to correct value:
Rotary encoder: Singleturn resolution (increments per revolution).
Linear encoder: Resolution of an increment (in nanometers).
Program Con-
tinuation:
Switch control OFF - ON.
311711 Axis %1 drive %2 transmission length SSI motor measuring system invalid
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: The configuration of the motor measuring system for an SSI encoder is incorrect:
MD_5028 $MD_NO_TRANSMISSION_BITS (SSI frame length) is smaller than the num-
ber of all parameterized bits in MD_5021 $MD_ENC_ABS_TURNS_MOTOR (multiturn),
MD_5022 $MD_ENC_ABS_RESOL_MOTOR (singleturn) and MD_5027
$MD_ENC_CONFIG bit 14 (alarm bit) and MD_5027 $MD_ENC_CONFIG bit 12 (parity
bit).

Other manuals for Siemens SINUMERIK 840D sl

Related product manuals