Overview of Alarms 08/2005
2-926
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
%2 = Parameter 1
%3 = Parameter 2
%4 = Parameter 3
Definitions: An operating error occurred on the PROFIBUS DP in cyclic mode.
Overview: Cause of the error, Par 1, Par 2, Par 3:
01 = unknown alarm, alarm class, logical address, --
02 = DPM cycle timeout, DPM actual value status, DPM setpoint value status, --
03 = DPM cycle status, DPM actual value status, DPM setpoint value status, DPM error
code
04 = DPM cycle error, DPM actual value status, DPM setpoint value status, DPM error
code
05 = client not registered, client number, max. number of clients, --
06 = synchronisation error, number of sync violation, --, --
07 = spinlock timeout, PLC spinlock, NCK spinlock
Digit 1000 of the error cause = number of the affected bus
Alarm class: (see alarm 380 060)
The following can be primary causes:
For error cause 01: Data transfer error on PROFIBUS DP
For error cause 02, 03, 04: Error in contents of SDB1000
For error cause 02, 03, 04, 05, 07: Corruption of parts of system program
For error cause 06: The PCI bus cycle does not match the expected rate and synchroni-
zation is not possible for this reason. The correct PCI bus cycle must be entered.
The error can also be caused by a hardware problem on the MCI module.
Reactions: - Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy: For error cause 01:
Check the electrical and fault-related specifications for PROFIBUS DP, assess the cable
installation
Check the terminating resistors of the PROFIBUS connectors (ON setting at end of
cable, otherwise OFF setting required)
Check slave
For error cause 02, 03, 04:
Check SDB1000
For error cause 02, 03, 04, 05:
Follow the procedure described for troubleshooting alarm 380 001
For error cause 06:
The correct PCI bus cycle must be entered.
If the error cannot be eliminated by this procedure, please make a note of the error text
and contact the control system manufacturer.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
380005 Profibus-DP: bus %3 access conflict, type %1, counter %2