Overview of Alarms 08/2005
2-940
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
400161 Delete DB 61 in the PLC and restart
Definitions: The DB created by the basic program and the existing DB differ in size.
Reactions: - Alarm display.
Remedy: Displayed DB must be deleted via STEP7. Possibly max. program size of the user pro-
gram exceeded.
Program Con-
tinuation:
Internal
400171 Delete DB 71 in the PLC and restart
Definitions: The DB created by the basic program and the existing DB differ in size.
Reactions: - Alarm display.
Remedy: Displayed DB must be deleted via STEP7. Possibly max. program size of the user pro-
gram exceeded.
Program Con-
tinuation:
Internal
400172 Delete DB 72 in the PLC and restart
Definitions: --
Reactions: - Alarm display.
Remedy: See the machine manufacturer's information.
Program Con-
tinuation:
Internal
400173 Delete DB 73 in the PLC and restart
Definitions: The DB created by the basic program and the existing DB differ in size.
Reactions: - Alarm display.
Remedy: Displayed DB must be deleted via STEP7. Possibly max. program size of the user pro-
gram exceeded.
Program Con-
tinuation:
Internal
400174 Delete DB 74 in the PLC and restart
Definitions: The DB created by the basic program and the existing DB differ in size.
Reactions: - Alarm display.
Remedy: Displayed DB must be deleted via STEP7. Possibly max. program size of the user pro-
gram exceeded.
Program Con-
tinuation:
Internal
400176 Delete DB 76 in the PLC and restart
Definitions: The DB created by the basic program and the existing DB differ in size.
Reactions: - Alarm display.
Remedy: Displayed DB must be deleted via STEP7. Possibly max. program size of the user pro-
gram exceeded.
Program Con-
tinuation:
Internal
400177 Delete DB 77 in the PLC and restart
Definitions: The DB created by the basic program and the existing DB differ in size.
Reactions: - Alarm display.
Remedy: Displayed DB must be deleted via STEP7. Possibly max. program size of the user pro-
gram exceeded.