List of Action Numbers 08/2005
3-954
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
No. 22
No. 23
No. 24
No. 25
Explanation Activate main run single block (OPI variable and VDI signal: Activate single block
Not allowed if -
Remedy -
Explanation Activate traversing single block (OPI variable and VDI signal: Activate single block)
Not allowed if -
Remedy -
Explanation Start program processing (VDI signal: NC Start).
Not allowed if Program status active.
An alarm reaction is pending which prevents a start or forces braking.
Reference point approach has not been performed yet.
Remedy Execute condition for clearing alarm
Reference point approach
Explanation Start program processing (channel communication, NC block: Start).
Not allowed if 1. Program status active.
2. An alarm reaction is pending which prevents a start or forces braking.
3. Reference point approach has not been performed yet.
4. An incorrect operating mode has been selected. (only Automatic).
Remedy Protect Start with WAITE
Execute condition for clearing alarm.
Reference point approach
Select program operating mode