08/2005 List of Action Numbers
3-961
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
No. 58
No. 59
No. 60
No. 61
No. 62
Explanation Wait for end of program (channel communication, NC block: WAITE).
Not allowed if -
Remedy -
Explanation Program selection from another channel, synchronously (channel communication, NC
block: INIT + SYNC).
Not allowed if -
Remedy -
Explanation Wait until acknowledgement from MMC (NC block, MMC_CMD)
Not allowed if -
Remedy -
Explanation Activate the skip-block function (VDI signal: Skip block).
Not allowed if Nesting depth too great.
Remedy Wait until the preceding ASUB is complete or
Abort program
Explanation Deactivate the skip-block function (VDI signal: Skip block).
Not allowed if Nesting depth too great.
Remedy Wait until the preceding ASUB is complete or
Abort program