08/2005 List of Action Numbers
3-967
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
No. 90
No. 91
No. 92
No. 93
No. 94
Explanation Activate all machine data with the attribute (NEW_CONF) (NC_block: NEW_CONF with
block search).
Not allowed if -
Remedy -
Explanation Start continuation of interpreter processing (internal preprocessing stop)
Not allowed if -
Remedy -
Explanation Save interlock for data.
Not allowed if The channel is not in the "stopped" state.
Remedy -
Explanation Activate user data, e.g., via MMC; newly modified tool lengths become active immedi-
ately in the running program
Not allowed if 1. The channel is not in the "stopped" state.
2. The channel is stopped and the current block cannot be reorganized.
Remedy − Press the Stop/Single-Block/Reset/StopAtEnd (Automatic) key.
− Activate a block change until the NC block can be reorganized.
Explanation Write the user PLC version to the version file.
Not allowed if -
Remedy -