08/2005 List of Action Numbers
3-967
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
No. 90
No. 91
No. 92
No. 93
No. 94
Explanation Activate all machine data with the attribute (NEW_CONF) (NC_block: NEW_CONF with
block search).
Not allowed if -
Remedy -
Explanation Start continuation of interpreter processing (internal preprocessing stop)
Not allowed if -
Remedy -
Explanation Save interlock for data.
Not allowed if The channel is not in the "stopped" state.
Remedy -
Explanation Activate user data, e.g., via MMC; newly modified tool lengths become active immedi-
ately in the running program
Not allowed if 1. The channel is not in the "stopped" state.
2. The channel is stopped and the current block cannot be reorganized.
Remedy Press the Stop/Single-Block/Reset/StopAtEnd (Automatic) key.
Activate a block change until the NC block can be reorganized.
Explanation Write the user PLC version to the version file.
Not allowed if -
Remedy -