08/2005 List of Action Numbers
3-971
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
No. 116
No. 117
No. 118
Explanation Activate tool-management commands (Ch. VDI signal).
Not allowed if The NCK channel is in a state other than "ready".
Remedy Abort the program or process with the Reset key or wait for end of program.
Explanation Deactivate tool-management commands (Ch. VDI signal).
Not allowed if The NCK channel is in a state other than "ready".
Remedy Abort the program or process with the Reset key or wait for end of program.
Explanation Selection of desired safety limitations (SGE) (always allowed).
Not allowed if -
Remedy -