EasyManuals Logo

Siemens SINUMERIK 840D sl Diagnostics Guide

Siemens SINUMERIK 840D sl
1002 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #989 background imageLoading...
Page #989 background image
08/2005 System Reactions on Alarms
5-989
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Names SHOWALARMAUTO
Effect The alarm is displayed whenever bit 0 of machine data ENABLE_ALARM_MASK is set.
The reaction should be set whenever an alarm should only occur during automatic
mode without manual operation by the user.
Alarm reaction in automatic mode
Names SHOWWARNING
Effect The alarm is displayed whenever bit 1 of machine data ENABLE_ALARM_MASK is set.
It is designed for warnings which should normally be suppressed.
Alarm view
Names ALLBAGS_NOREADY
Effect The Ready is canceled in all mode groups. The reaction thus corresponds to an NCK-
REACTIONVIEW|NOREADY, the difference being that the NC READY relay is not can-
celed and the corresponding VDI bit is not set. This is desirable in the event of an
emergency stop for example.
Mode group not ready
Names DELAY_ALARM_REACTION
Effect If this alarm reaction is configured in the alarm handler, all alarm reactions for alarms,
which occur at this point, are buffered channel-specifically and are, therefore, not active.
The alarms are displayed on the MMC. Mode group and NC-wide reactions are trans-
ferred. The reaction is cleared by activating the clearDelayReaction call or by an alarm,
which has configured NO_DELAY_ALARM_REACTION. This activates all the delayed
alarm reactions.
All channel-specific alarm reactions delayed on alarm, alarm display
Names NO_DELAY_ALARM_REACTION
Effect The DELAY_ALARM_REACTION state is canceled.
The alarm reaction delay is canceled.
Names ONE_IPO_CLOCK_DELAY_ALARM_REACTION
Effect All alarm reactions are delayed by one cycle when an alarm is output. This functionality
became necessary as part of ESR development.
All alarm reactions are delayed by one IPO cycle on alarm.

Other manuals for Siemens SINUMERIK 840D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl and is the answer not in the manual?

Siemens SINUMERIK 840D sl Specifications

General IconGeneral
Control TypeCNC
Number of AxesUp to 31
Max Number of Channels10
InterfacesEthernet, PROFIBUS, PROFINET, USB
Interpolation5-axis interpolation
Operating Temperature0°C to 45°C
Relative HumidityUp to 95% (non-condensing)
DisplayTFT color display, various sizes
Programming LanguagesDIN/ISO
Safety FeaturesSafety Integrated
PLCIntegrated PLC S7-300
Drive InterfaceSINAMICS S120
Data StorageCF card, USB
Operating SystemWindows-based

Related product manuals