Overview of Alarms 11/2006
NCK alarms
2-568
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
61805 Channel %1 block %2: Value programmed absolute and incremental
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The programmed intermediate position is both absolutely as well as incrementally programmed.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program
Continuation:
Internal
61806 Channel %1 block %2: Wrong axis assignment
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The axis-assignment sequence is wrong.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program
Continuation:
Internal
61807 Channel %1 block %2: Wrong spindle direction programmed (active)
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycle: CYCLE840.
The programmed spindle direction contradicts the spindle direction planned for the cycle.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check parameters SDR and SDAC.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61808 Channel %1 block %2: Final drilling depth or single drilling depth
missing
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The total depth Z or individual drilling depth Q is missing from theG8xblock (initial cycle call).
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program
Continuation:
Internal