NCK alarms
11/2006 Overview of Alarms
2-569
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
61809 Channel %1 Block %2: Drill position not permissible
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: --
Reaction: Alarm display.
Remedy: --
Program
Continuation:
Internal
61810 Channel %1 Block %2: ISO G code not possible
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In the call block an impermissible ISO axis name was programmed.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program
Continuation:
Internal
61811 Channel %1 Block %2: ISO axis name illegal
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In the call block an impermissible numerical value was programmed.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program
Continuation:
Internal
61812 Channel %1 Block %2: Value(s) in external cycle call wrongly defined
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In the call block an impermissible numerical value was programmed.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program
Continuation:
Internal
61813 Channel %1 Block %2: GUD value wrongly defined
Definitions: An impermissible numerical value was
entered in the cycles-setting data.
Reaction: Alarm display.
Remedy: --
Program
Continuation:
Internal