Overview of Alarms 11/2006
NCK alarms
2-570
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
61814 Channel %1 block %2: Polar coordinates not possible with cycle
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: --
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program
Continuation:
Internal
61815 Channel %1 block %2: G40 not active
Parameters: %1 = Channel number
%2 = Block number
Definitions: G40 was inactive before the cycle call.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program
Continuation:
Internal
61816 Channel %1 Block %2: Axes not on reference point
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: --
Reaction: Alarm display.
Remedy: --
Program
Continuation:
Internal
61817 Channel %1 Block %2: Axis coordinates within protection zone
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: --
Reaction: Alarm display.
Remedy: --
Program
Continuation:
Internal
61818 Channel %1 Block %2: Axis range limits are equal
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: --
Reaction: Alarm display.
Remedy: --
Program
Continuation:
Internal