EasyManuals Logo

Siemens SINUMERIK 840D Diagnostic Manual

Siemens SINUMERIK 840D
880 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #579 background imageLoading...
Page #579 background image
NCK alarms
11/2006 Overview of Alarms
2-579
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
62304 Channel %1 Block %2: Allowance
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE974, CYCLE977, CYCLE978, CYCLE979,
CYCLE994.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: The difference between actual and setpoint value is larger than upper tolerance limit (parameter
_TUL).
Program
Continuation:
Clear alarm with the RESET key. Restart part program
62305 Channel %1 Block %2: Dimension too small
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE974, CYCLE977, CYCLE978, CYCLE979,
CYCLE994
Remedy: The difference between actual and setpoint value is smaller than lower tolerance limit (parameter
_TLL).
62306 Channel %1 Block %2: Permissible measuring difference exceeded
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE971, CYCLE972, CYCLE974, CYCLE977,
CYCLE978, CYCLE979, CYCLE982, CYCLE994
Remedy: The difference between actual and setpoint value is larger than tolerance parameter _TDIF, tool data
are not corrected.
62307 Channel %1 block %2: Maximum number of characters per line
exceeded.
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE105
Insufficient number of characters per line.
Remedy: Increase the value in _PROTFORM[1]
62308 Channel %1 Block %2: Variable column width not possible
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE105.
Unable to generate variable column widths, as no header available.
A fixed column width of 12 characters is used.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Complete the header in _PROTVAL[0].
Program
Continuation:
Clear alarm with the RESET key. Restart part program

Other manuals for Siemens SINUMERIK 840D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D and is the answer not in the manual?

Siemens SINUMERIK 840D Specifications

General IconGeneral
SeriesSINUMERIK 840D
AxesUp to 31
ChannelsUp to 10
Operating SystemWindows-based
Power Supply24 V DC
Control Unit TypeCNC
InterfaceEthernet, PROFIBUS
DisplayTFT color display
InterpolationSpline
PLCIntegrated PLC
Data StorageCompactFlash, USB

Related product manuals