NCK alarms
11/2006 Overview of Alarms
2-537
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
61311 Channel %1 Block %2: No D number active
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: No tool offset for the measuring probe (for workpiece measurement) or no tool offset for the active tool
(for tool measurement) is selected.
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy: Select the tool's tool edge number D.
61312 Channel %1 Block %2: Check measuring cycle number
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The alarm can be triggered by the following measuring cycles: all measuring cycles.
Remedy: Measuring cycle called is impermissible...
61313 Channel %1 Block %2: Check probe number
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The probe has an impermissible value (_PRNUM).
The alarm can be triggered by the following measuring cycles: all measuring cycles.
Remedy: Correct _PRNUM or create data field _TP[] or _WP[] for additional tool or workpiece probe
and adjust _CVAL[0]/_CVAL[1] accordingly.
61314 Channel %1 Block %2: Check selected tool type
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm is triggered: CYCLE971, CYCLE972, CYCLE982.
Remedy: Tool type impermissible for tool measurement/tool probe calibration.
61315 Channel %1 Block %2: Check position of cutting edge
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm is triggered: CYCLE972, CYCLE973, CYCLE974, CYCLE982, CYCLE994.
Remedy: Check tool edge position (probe) in TO memory.
61316 Channel %1 Block %2: Center and radius cannot be determined
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: No circle can be calculated from the measured points, as all measured points lie on a straight line.
The alarm is triggered by: CYCLE979
Remedy: Program change
61317 Channel %1 Block %2: Check parameter CYCLE116
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Parameterization faulty; requires 3 or 4 points to calculate the center point. Alarm is triggered:
CYCLE979.
Remedy: Change parameterization of CYCLE116.