Overview of Alarms 11/2006
NCK alarms
2-538
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
61318 Channel %1 Block %2: Check weighting factor _K
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Parameter _K is 0. Alarm is triggered: CYCLE974, CYCLE977, CYCLE978, CYCLE979, CYCLE994,
CYCLE998.
Remedy: Check parameter _K.
61319 Channel %1 Block %2: Check call parameter CYCLE114
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Internal error in measuring cycles. Alarm is triggered: CYCLE974, CYCLE977, CYCLE978,
CYCLE979, CYCLE994, CYCLE998.
Remedy: Check call parameter CYCLE114.
61320 Channel %1 Block %2: Check tool number
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: With active tool management, parameter _TNUM=0 and parameter _TNAME is not set or
the specified tool name of tool management is unknown.
The alarm can be triggered by the following measuring cycles: all measuring cycles.
Remedy: Check parameter _TNUM, _TNAME.
61321 Channel %1 Block %2: Check WO memory number
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: WO with the number specified in _KNUM not existing. Alarm is triggered: CYCLE974, CYCLE977,
CYCLE978, CYCLE979, CYCLE994, CYCLE998.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check parameter _KNUM.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61322 Channel %1 Block %2: Check 4th number of _KNUM
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The specified position of _KNUM includes invalid values. Also check _MVAR.
Alarm is triggered: CYCLE974, CYCLE977, CYCLE978, CYCLE979, CYCLE994, CYCLE998,
CYCLE114.
Remedy: Check parameter _KNUM, _MVAR.
61323 Channel %1 Block %2: Check 5th number of _KNUM
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The specified position of _KNUM includes invalid values. Also check _MVAR.
Alarm is triggered: CYCLE974, CYCLE977, CYCLE978, CYCLE979, CYCLE994, CYCLE998,
CYCLE114.
Remedy: Check parameter _KNUM, _MVAR.