NCK alarms
11/2006 Overview of Alarms
2-539
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
61324 Channel %1 Block %2: Check 6th number of _KNUM
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The specified position of _KNUM includes invalid values. Also check _MVAR.
Alarm is triggered: CYCLE974, CYCLE977, CYCLE978, CYCLE979, CYCLE994, CYCLE998,
CYCLE114.
Remedy: Check parameter _KNUM, _MVAR.
61325 Channel %1 Block %2: Check measuring axis/auxiliary measuring axis
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Parameter for metering shaft _MA has an incorrect value.
Alarm is triggered by: all measuring cycles except for CYCLE979.
Remedy: Check parameter _MA.
61326 Channel %1 Block %2: Check measuring direction
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Parameter for measuring direction _MD has an incorrect value. Alarm is triggered: CYCLE973,
CYCLE976.
Remedy: Check parameter _MD.
61327 Channel %1 Block %2: Program reset required
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: NC reset required.
Alarm is triggered: all measuring cycles except for CYCLE973, CYCLE976.
Remedy: Execute NC reset.
61328 Channel %1 Block %2: Check D number
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: D number in parameter _KNUM is 0.
The alarm can be triggered by all measuring cycles.
Remedy: Check parameter _KNUM.
61329 Channel %1 Block %2: Check rotary axis
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: No name assigned to the axis number specified under parameter _RA or axis not configured as rotary
axis. Alarm is triggered: CYCLE998.
Remedy: Check MD 20080 or MD 30300.
61330 Channel %1 Block %2: Coordinate rotation active
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: No measuring possible in the rotated coordinate system. Alarm is triggered: CYCLE972, CYCLE973,
CYCLE974, CYCLE994.
Remedy: Check the conditions for measuring.