Overview of Alarms 11/2006
NCK alarms
2-540
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
61331 Channel %1 Block %2: Angle too large, change measuring axis
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Parameter _STA is too large of the specified metering shaft. Alarm is triggered: CYCLE998.
Remedy: Select another metering axis.
61332 Channel %1 Block %2: Modify tool tip position
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The tool tip is below the measuring probe surface (e.g. for a ring gauge or cube). Alarm is triggered:
CYCLE971, CYLCE972, CYCLE982, E_MT_CAL, E_MT_LEN, E_MT_RAD.
Remedy: Place the tool above the measuring probe surface.
61333 Channel %1 Block %2: Check calibration facility number
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Parameter _CALNUM is too large. Alarm is triggered: CYCLE973.
Remedy: Reduce _CALNUM to a permissible value or increase maximum value _CVAL[2] in GUD6.
61334 Channel %1 Block %2: Check safety area
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Parameter _SZA, _SZO too large or too small. Alarm is triggered: CYCLE977.
Remedy: Check parameter _SZA, _SZO.
61336 Channel %1 Block %2: Geometry axes do not exist
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: No geometry axes configured. Alarm can be triggered by following measuring cycles: all measuring
cycles.
Remedy: Machine data in MD 20060 must be changed.
61337 Channel %1 Block %2: Check measuring input
Parameters: %1 = Channel number
%2 = Block number, label
Definitions:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61338 Channel %1 Block %2: Positioning speed equal to zero
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: For some measuring versions, for example measuring spigots, in addition to the actual measuring
paths, intermediate paths are generated that are traversed with a specified feed. The values for the
feed are specified in parameters _SPEED[1] and _SPEED[2] in GUD6.
Alarm triggered by following measuring cycles: all measuring cycles.
Remedy: Check parameter _SPEED[1], _SPEED[2] in GUD6.