Emergency stop button
Rated voltage 24 V DC
Current rating, max. 3 A
Current rating, min. 1 mA
Switching capacity DC 13 according to EN 60947-5-1
Conditional rated short-circuit current 10 A gL/gG according to EN 60947-5-1
B
10d
500 000
Note
The quantitative assessment of the emergency stop safety function must be based on the B
10d
values corresponding to the used standards (e.g. ISO 13849-1) under consideration of the
respective application (frequency of the actuation, service life, diagnostics by the evaluation
unit, etc.). The B
10d
values only apply when the technical properties of the emergency stop
button are taken into account.
Technical data
ONE MCP Part 2: MCP 2400
Equipment Manual, 08/2023, A5E50324707B AB 25