EasyManua.ls Logo

Siemens SINUMERIK ONE NCU 1750 - Page 81

Siemens SINUMERIK ONE NCU 1750
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Pin assignment
Table 8-18 X122 digital inputs/outputs
Pin Signal
name
Signal
type
Meaning Default set‐
ting
1 DI0 I Digital input 0
Input ON/OFF1 infeed (if one infeed with a DRIVE-CLiQ
connection is operated at the NCU)
x
2 DI1 I Digital input 1
Input 2. Operating condition OFF3 drives
"OFF3 – rapid stop"
Braking with a con󹪝gurable OFF3 ramp (p1135, p1136,
p1137); thereafter, pulse suppression and switching on
inhibited. The drive stops controlled. The braking re‐
sponse can be set separately for each SERVO.
x
3 DI2 I Digital input 2
Selection safe standstill group 1
SH/SBC - Group 1 SINAMICS Safety Integrated (SH =
p9601 release)
---
4 DI3 I Digital input 3
Selection safe standstill group 2
SH/SBC - Group 2 SINAMICS Safety Integrated (SH =
p9601 release)
---
5 DI16 I Digital input 16
Freely available
---
6 DI17 I Digital input 17
Freely available
---
7 G1 GND Ground for DI0 - DI3, DI16, DI17 (isolated with respect
to M)
8 M GND Ground for DI8 - DI11
9 DI/DO8 B Digital input/output 8 (rapid input)
Status safe standstill group 1
SH/SBC - Group 1
SINAMICS Safety Integrated
---
10 DI/DO9 B Digital input/output 9 (rapid input)
Status safe standstill group 2
SH/SBC - Group 2
SINAMICS Safety Integrated
---
11 M GND Ground for DI8 - DI11 ---
12 DI/DO10 B Digital input/output 10 (rapid input)
Input, external zero mark - BERO 1
---
13 DI/DO11 B Digital input/output 11
(rapid input)
Input, probe 1 - central
measuring (check that
MD13210 = 0)
x
Input, probe 1 - distributed
measurement (check that
MD13210 = 1)
---
Connecting
8.10 Digital inputs/outputs
NCU 1750
Equipment Manual, 01/2022, A5E45627807B AE 81