EasyManua.ls Logo

Siemens SINUMERIK ONE NCU 1750 - Page 82

Siemens SINUMERIK ONE NCU 1750
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Pin Signal
name
Signal
type
Meaning Default set‐
ting
14 M GND Ground for DI8 - DI11
Signal type: B = Bidirectional; I = Input; GND = Reference potential (ground)
In the "Default setting" column, the signals for which the associated SINAMICS parameters are set when
con󹪝guring a SINAMICS device are marked with "x".
Table 8-19 X132 digital inputs/outputs
Pin Signal
name
Signal
type
Meaning Default set‐
ting
1 DI4 I Digital input 4
Freely available
---
2 DI5 I Digital input 5
Freely available
---
3 DI6 I Digital input 6
Freely available
---
4 DI7 I Digital input 7
Infeed line contactor feedback (if one infeed is operated
with a DRIVE-CLiQ connection at the NCU)
---
5 DI20 I Digital input 20
Freely available
---
6 DI21 I Digital input 21
Freely available
---
7 G2 GND Ground for DI4 – DI7 (functionally-separated relative to
M)
8 M GND Ground for DI12 - DI15
9 DI/DO12 B Digital input/output 12
(rapid input)
Output: Infeed operation
(if one infeed is operated
with a DRIVE-CLiQ connec‐
tion at the NCU)
x
Input 2. Operating condi‐
tion OFF2 drives
---
10 DI/DO13 B Digital input/output 13
(rapid input)
Output: Status, infeed
ready to start (if one infeed
is operated at the NCU with
a DRIVE-CLiQ connection)
x
Input 2. Operating condi‐
tion OFF2 drives
---
Input, external zero mark 2 ---
Input probe 2 - central
measurement
---
Input probe 2 - distributed
measurement
---
11 M GND Ground for DI12 - DI15
Connecting
8.10 Digital inputs/outputs
NCU 1750
82 Equipment Manual, 01/2022, A5E45627807B AE