Using the system
62
Building Technologies 052_SiPass_Entro_6_5_A24205-A335-B318_e_en
Fire Safety & Security Products 10.03.2010
Only caretakers can reset any common alarm
at a reader keypad.
24.6 Caretaker functions
Some doors can be configured to allow for a temporary change of security level.
The door can be set Unlocked for certain times - or set to Group code (4 digits).
The command is invoked at - and applies only to – a selected door.
The prerequisite is that the person doing this must belong to an access group with
the Caretaker tick box selected.
24.6.1 Unlocked
There are three different commands for a Caretaker to unlock the door.
A18 All caretakers can then reset/lock the door.
A19 Only the very same caretaker
can then reset/lock the door.
A20 All authorized card holders can then reset/lock the door.
Proceed as follows:
1. Press A18, A19 or A20 and the yellow LED flashes three times.
2. Use the card (+ PIN).
The yellow LED is lit.
3. Enter the time when the door is to be locked again. E g 1600 for 4 PM.
The reader sets the door unlocked until the requested time (or a time zone
change).
24.6.2 Group code
Proceed as follows:
1. Press A21 and the yellow LED flashes three times.
2. Use the card (+ PIN). The yellow LED is lit.
3. Enter the time when the door is to be locked again. E g 1600 for 4 PM.
4. Enter the group code with four digits (not 0000).
The yellow LED flashes once and the group code will work until the requested
time (or a time zone change). Remote opening from PC will still work.