Minimum -40 dBm ± 2 dBm
Spectrum 400 nm to 1100 nm
Attenuation In the case of plastic optical fibers, you can expect a path attenuation of
0.2 dB/m Additional attenuation comes from the plug and sensor head.
Optical budget
1
Minimal 25 dB
Analog sampling rate 16 kHz
ADC type 10-bit successive approximation
Transmitter
Type LED
Wavelength λ = 650 nm
Transmit power Minimum 0 dBm
Maximum 2 dBm
Numerical aperture
0.5
2
Signal rate connection test 1 pulse per second
Pulse duration connection test 11 μs
Comment:
1
All values in combination with sensors approved by Siemens.
2
Numerical aperture (NA = sin θ (launch angle))
High-Speed Measuring-Transducer Inputs, Voltage/Current (via IO210, IO212)
i
i
NOTE
Current and voltage may not be connected to a measuring-transducer input at the same time; only either
current or voltage may be connected. Due to EMC, no line may be connected to an input that is not used
(current or voltage).
Use shielded cables.
Table 11-1 High-Speed Measuring-Transducer Inputs, Voltage
Differential voltage input channels
8
9
Measuring range DC -10 V to +10 V
Fault < 0.5 % of the measuring range
Input impedance
48 kΩ
Conversion principle Delta-sigma (16 bit)
Permissible potential difference
between channels
DC 3.5 kV
Galvanic separation from ground/
housing
DC 3.5 kV
Permissible overload DC 20 V continuously
DC 60 V continuously (IO210 MT3 terminal point C9)
Measurement repetition 62.5 μs
Table 11-2 High-Speed Measuring-Transducer Inputs, Current
Differential current input channels
8
10
Measuring range DC -20 mA to +20 mA
Fault < 0.5 % of the measuring range
Input impedance, current
12 Ω
9
The IO212 has 8 high-speed measuring-transducer inputs. They can be used either as a voltage or as a current input.
10
The IO212 has 8 high-speed measuring-transducer inputs. They can be used either as a voltage or as a current input.
Technical Data
11.1 General Device Data
556 SIPROTEC 5, Low-Impedance Busbar Protection 7SS85, Manual
C53000-G5040-C019-6, Edition 06.2016

Other manuals for Siemens Siprotec 5 7SS85

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Siprotec 5 7SS85 and is the answer not in the manual?

Siemens Siprotec 5 7SS85 Specifications

General IconGeneral
BrandSiemens
ModelSiprotec 5 7SS85
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals