)NTRODUCTION3*
6
#
' #

 )MPLEMENTED FUNCTIONS
3)02/4%# 3* CONTAINS THE FOLLOWING FUNCTIONS
/VERCURRENT TIME PROTECTION
HIGH SET PHASE CURRENT STAGE ) WITH PHASE
SEGREGATED FAULT DETECTION AND PHASE SEGREGATED
DELAY TIMERS
HIGH SET EARTH CURRENT STAGE )
%
 WITH INDIVIDUAL
DELAY TIMER
INVERSE TIME PHASE OVERCURRENT STAGE )
P
WITH
PHASE SEGREGATED FAULT DETECTION AND PHASE SEG
REGATED DELAY TIMERS
ALTERNATIVELY DEFINITE TIME PHASE OVERCURRENT
STAGE ) WITH PHASE SEGREGATED FAULT DETECTION
AND PHASE SEGREGATED DELAY TIMERS
INVERSE TIME EARTH OVERCURRENT STAGE )
%P
WITH INDI
VIDUAL DELAY TIMER
ALTERNATIVELY DEFINITE TIME EARTH OVERCURRENT STAGE
)
%
WITH INDIVIDUAL DELAY TIMER
DIFFERENT CURRENT TIME CHARACTERISTICS CAN BE SET
FOR PHASE CURRENTS AND EARTH CURRENT
FOR PHASE CURRENTS SELECTION CAN BE MADE OF
THREE STANDARDIZED CHARACTERISTICS ACCORDING TO
)%# OR OF EIGHT STANDARDIZED CHARACTERISTICS AC
CORDING !.3))%%% OF INVERSE TIME OVERCURRENT
PROTECTION
FOR EARTH CURRENT SELECTION CAN BE MADE OF FOUR
STANDARDIZED CHARACTERISTICS ACCORDING TO )%# OR
OF EIGHT STANDARDIZED CHARACTERISTICS ACCORDING
!.3))%%% OF INVERSE TIME OVERCURRENT PROTECTION
ALTERNATIVELY A USER SPECIFIED CURRENT TIME CHARAC
TERISTIC CAN BE DEFINED
$IRECTIONAL OVERCURRENT TIME PROTECTION
DIRECTIONAL HIGH SET PHASE CURRENT STAGE )
WITH PHASE SEGREGATED FAULT DETECTION AND PHASE
SEGREGATED DELAY TIMERS
DIRECTIONAL HIGH SET EARTH CURRENT STAGE )
%

WITH INDIVIDUAL DELAY TIMER
DIRECTIONAL INVERSE TIME PHASE OVERCURRENT STAGE
)
P
WITH PHASE SEGREGATED FAULT DETECTION AND
PHASE SEGREGATED DELAY TIMERS
ALTERNATIVELY DIRECTIONAL DEFINITE TIME PHASE OVER
CURRENT STAGE ) WITH PHASE SEGREGATED FAULT DE
TECTION AND PHASE SEGREGATED DELAY TIMERS
DIRECTIONAL INVERSE TIME EARTH OVERCURRENT STAGE
)
%P
WITH INDIVIDUAL DELAY TIMER
ALTERNATIVELY DIRECTIONAL DEFINITE TIME EARTH OVER
CURRENT STAGE )
%
WITH INDIVIDUAL DELAY TIMER
DIFFERENT CURRENT TIME CHARACTERISTICS CAN BE SET
FOR PHASE CURRENTS AND EARTH CURRENT
FOR PHASE CURRENTS SELECTION CAN BE MADE OF
THREE STANDARDIZED CHARACTERISTICS ACCORDING TO
)%# OR OF EIGHT STANDARDIZED CHARACTERISTICS AC
CORDING !.3))%%% OF INVERSE TIME OVERCURRENT
PROTECTION
FOR EARTH CURRENT SELECTION CAN BE MADE OF FOUR
STANDARDIZED CHARACTERISTICS ACCORDING TO )%# OR
OF EIGHT STANDARDIZED CHARACTERISTICS ACCORDING
!.3))%%% OF INVERSE TIME OVERCURRENT PROTECTION
ALTERNATIVELY A USER SPECIFIED CURRENT TIME CHARAC
TERISTIC CAN BE DEFINED
OPERATION DIRECTION INDIVIDUALLY SELECTABLE FOR
EACH OF THESE STAGES FORWARDS OR RESERVE
THE NORMAL OVERCURRENT TIME STAGES REMAIN EFFEC
TIVE AS BACK
UP STAGES
%ARTH FAULT DETECTION
DISPLACEMENT VOLTAGE DETECTION FOR EARTH FAULT AN
NUNCIATION AND OPTIONAL TRIP
DETECTION OF THE EARTH FAULTED PHASE WHEN USED
IN ISOLATED OR COMPENSATED SYSTEMS
ONLY FOR MODEL 3*J JJJJ JJJJ
www . ElectricalPartManuals . com