)NTRODUCTION3*
6

#
' #
4HE FOLLOWING FEATURES OF EARTH FAULT DETECTION ONLY IN
MODEL 3* J
JJJJ JJJJ
TWO STAGE EARTH CURRENT DETECTION HIGH VALUE
STAGE )
%%
 AND LOW VALUE STAGE )
%%

CAN BE SET INDEPENDENT OF THE OVERCURRENT TIME
PROTECTION STAGES FOR HIGHLY SENSITIVE EARTH FAULT
DETECTION SMALLEST PICK
UP VALUE  !
LOW VALUE STAGE WITH INVERSE TIME LAG OR SELECT
ABLE DEFINITE TIME LAG
A USER DEFINED INVERSE TIME CHARACTERISTIC CAN BE
DEFINED
EACH STAGE CAN BE SET DIRECTIONAL FORWARDS OR RE
VERSE OR NON
DIRECTIONAL
ADJUSTABLE DIRECTIONAL CHARACTERISTIC
CAN BE SET TO TRIP OR TO ALARM ONLY
COMPENSATION OF CURRENT TRANSFORMER ANGLE ERROR
WHEN USED IN COMPENSATED SYSTEMS
$EAD
FAULT PROTECTION
PROVIDES HIGH SPEED OPERATION WHEN SWITCHING
MANUALLY ONTO A BOLTED FAULT
!UTOMATIC RECLOSE FUNCTION
SINGLE OR MULTI SHOT EG 2!2 AND $!2
WITH SEPARATELY ALLOCATED ACTION TIMES FOR 2!2
RAPID !2 FOR FIRST SHOT AND $!2 DELAYED !2 FOR
FURTHER SHOTS
WITH SEPARATELY ALLOCATED DEAD TIMES FOR 2!2
RAPID !2 FOR FIRST SHOT AND $!2 DELAYED !2 FOR
FURTHER SHOTS INDIVIDUALLY AFTER SINGLE
PHASE
FAULT AND AFTER MULTI
PHASE FAULTS
SELECTION CAN BE MADE WHICH OF THE OVERCURRENT
AND EARTH FAULT STAGES DO OPERATE WITH !2 AND
WHICH DO NOT
$ISTANCE
TO FAULT LOCATION
CAN BE STARTED BY FAULT DETECTION OF OVERCURRENT
TIME PROTECTION TRIP COMMAND OR BY EXTERNAL
COMMAND
CALCULATION OF THE FAULT DISTANCE AND OUTPUT OF THE
FAULT DISTANCE IN /HMS SECONDARY AN KILOMETERS
OR MILES
#IRCUIT BREAKER FAILURE PROTECTION
CURRENT MONITORING ANDOR PROCESSING OF THE
BREAKER AUXILIARY CONTACTS
INITIATION BY EACH OF THE INTEGRATED PROTECTION
FUNCTIONS WHICH LEAD TO TRIP
INITIATION POSSIBLE FROM EXTERNAL PROTECTION DEVICE
VIA BINARY INPUT
INITIATION POSSIBLE FROM INTEGRATED BREAKER CON
TROL
5NBALANCED LOAD PROTECTION
PROCESSING OF THE NEGATIVE SEQUENCE COMPONENT
OF THE CURRENTS
TWO STAGE TRIP CHARACTERISTIC
4HERMAL OVERLOAD PROTECTION
PROVIDES THERMAL REPLICA OF THE CURRENT HEAT LOSSES
WITH TOTAL MEMORY
TRUE RMS MEASUREMENT OF ALL THREE CONDUCTOR
CURRENTS
ADJUSTABLE THERMAL WARNING STAGE
ADJUSTABLE CURRENT WARNING STAGE
ADJUSTABLE COOLING DOWN FACTOR POSSIBLE FOR USE
ON MOTORS
3TART
UP TIME MONITOR FOR USE ON MOTORS
CURRENT DEPENDENT TRIP TIME BY PROCESSING OF THE
START
UP CURRENT OF THE MOTOR
CURRENT INDEPENDENT DELAY TIME WHEN THE ROTOR IS
LOCKED
2ESTART LOCKOUT FOR MOTORS OPTIONAL
APPROXIMATION OF THE ROTOR TEMPERATURE RISE
RELEASE OF RESTART OF THE MOTOR ONLY BELOW A SELECT
ABLE RESTART LIMIT
CONSIDERATION OF THE SHUT DOWN PROCEDURE AND
REDUCED COOLING EFFECT DURING STAND
STILL
LOCKOUT CAN BE AVOIDED FOR EMERGENCY RUN UP OF
THE MOTOR
ONLY FOR MODEL 3*J JJJJ JJJJ