Page #1 background image
SITRANS LT500 with ultrasonic transducer inputs
SITRANS L
Controllers
SITRANS LT500 with ultrasonic
transducer inputs
Compact Operating Instructions
7ML60.. (SITRANS LT500 with ultrasonic transducer
inputs)
02/2024
A5E52021877
-AA
Getting started
1
Introduction
2
Safety notes
3
Installing/mounting
4
Connecting
5
Commissioning
6
Service and maintenance
7
Technical specifications
8
Product documentation and
support
A

Table of Contents

Other manuals for Siemens SITRANS LT500

Question and Answer IconNeed help?

Do you have a question about the Siemens SITRANS LT500 and is the answer not in the manual?

Siemens SITRANS LT500 Specifications

General IconGeneral
Device TypeLevel Transmitter
Measurement PrincipleUltrasonic
Output Signal4-20 mA, HART
Power Supply12 to 36 V DC
Process Temperature-40 to +85 °C (-40 to +185 °F)
Process PressureUp to 3 bar (43.5 psi)
Enclosure RatingIP66/IP67, Type 4X
CommunicationHART
MaterialStainless steel
ApplicationLevel, volume and flow measurement in a wide range of industries and applications

Summary

Getting Started

Safety Notes

Preconditions for Use

Emphasizes observing instructions and symbols on the device for safe operation and maintenance.

Use in Hazardous Areas

Details qualifications required for personnel and safety precautions when operating in hazardous environments.

Installing and Mounting

Installing and Mounting the Device

Provides general installation guidelines, requirements, and things to avoid for proper setup.

Connecting

Connecting SITRANS LT500

Illustrates the overall connection scheme and identifies various connection points and devices.

Hazardous Area Installations

Details safety warnings regarding improper power supply in hazardous areas.

Commissioning

Basic Safety Notes

Highlights dangers of toxic gases, hazardous voltage, and improper commissioning in hazardous areas.

Local Operation

Describes the device's HMI for quick commissioning using local buttons and display.

Device Startup

Guides through the initial power-on process, including language, date/time, and quick commissioning wizard.

Local Commissioning

Explains the process of using quick start wizards to configure the device for various applications.

Service and Maintenance

Basic Safety Notes

Stresses periodic inspection and precautions against moisture penetration during work.

Maintenance and Repair Work

States that repairs must be by authorized personnel and warns about hazardous voltage when open.