Technical specifications
8.8 Communication
SITRANS LT500 with ultrasonic transducer inputs
108 Compact Operating Instructions, 02/2024, A5E52021877-AA
HART Physical layer (2 wire half duplex, HART FSK)
0 to 63 (Set via communication or HMI)
The HART long address is bound to the specific card installed. If this card is replaced the
master system will need to be updated.
EIA-RS485 (2 wire half duplex)
External 120R resistor across Fieldbus connections 35 and 36
Set by Modbus or HMI range from 1 to 247
Even parity, 1 stop bit (default)
Byte order adjustable via Modbus or HMI, default Big endian