Installing/mounting
4.2 Installing/mounting the device
SITRANS LT500 with ultrasonic transducer inputs
Compact Operating Instructions, 02/2024, A5E52021877-AA
19
Procedure
1. Unscrew the lid (six screws) and open it to reveal the mounting holes.
2. Mark and drill four holes in the mounting surface for the four screws (customer supplied).
3. Fasten with a long screwdriver.
4. Add conduit or cable glands if applicable to application and wire as required:
– Attach the conduit to the gland before connecting the gland to the enclosure.
– Unscrew the glands and attach them loosely to the enclosure. Use only approved
suitable-sized glands for watertight applications.
– Thread the cables through the conduit/glands.
To avoid interference, ensure that the power cable is kept separated from the signal
cables, and then wire the cables to the terminal blocks.
– Tighten the glands to form a good seal.
5. Screw the lid in place noting recommended torque values.