EasyManua.ls Logo

Siemens SITRANS LT500 - Page 59

Siemens SITRANS LT500
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commissioning
6.5 Local commissioning
SITRANS LT500 with ultrasonic transducer inputs
Compact Operating Instructions, 02/2024, A5E52021877-AA
59
Length units
Sets the length units applied for local operation and the communication interface, on
measurement point 1 and 2.
Setting
m (meters)
cm (centimeters)
mm (millimeters)
ft (feet)
in (inches)
Default
m
Note
Process value too large to display
In some cases, it is possible that the process value is too large to show on the local display,
"
#####" will show instead.
If this occurs in a typical application:
Adjust parameter "Units" so that a smaller value can be shown, e.g. use meters instead of
millimeters.
If this occurs in a custom application:
Adjust parameter "Custom units" so that a smaller value can be shown, e.g. use tons
instead of pounds.
Note that a change to custom units also requires a manual scaling adjustment.

Table of Contents

Other manuals for Siemens SITRANS LT500

Related product manuals