Commissioning
6.5 Local commissioning
SITRANS LT500 with ultrasonic transducer inputs
Compact Operating Instructions, 02/2024, A5E52021877-AA
75
Volume units
Sets the volume units for totalizers, applied for local operation and the communication
interface.
For measurement point 1, volume units are set for totalizer 1 and 2.
For measurement point 2, volume units are set for totalizer 3 and 4.
Setting
l (liters)
hl (hectoliters)
m
3
(cubic meters)
gal (UK) (imperial gallons)
in
3
(cubic inches)
gal (US gallons)
ft
3
(cubic feet)
bu (bushels)
bbl-beer (31 US gallon barrels)
bbl (US) (31.5 gallon barrels)
bbl (42 US gallon barrels)
yd
3
(cubic yards)
Mgal (US megagallons)
Ml (megaliters)
Custom
Default
l (liters)
Note
Process value too large to display
In some cases, it is possible that the process value is too large to show on the local display,
"
#####" will show instead.
If this occurs in a typical application:
Adjust parameter "Units" so that a smaller value can be shown, e.g. use meters instead of
millimeters.
If this occurs in a custom application:
Adjust parameter "Custom units" so that a smaller value can be shown, e.g. use tons
instead of pounds.
Note that a change to custom units also requires a manual scaling adjustment.