SITRANS P, DS III series (7MF4.33.. 7MF4.34.. 7MF4.35..)
A5E03434645-01, 08/2011
39
Operating conditions
Rated conditions for gauge pressure and absolute pressure (from the gauge pressure series)
Installation conditions
Ambient conditions
Ambient temperature
Note Observe the temperature class in hazardous areas.
Measuring cell with silicon oil
filling
-40 … +85 °C (-40 … +185 °F)
Measuring cell with inert liquid -20 … +85 °C (-4 … +185 °F)
Display -30 … +85 °C (-22 … +185 °F)
Storage temperature -50 … +85 °C (-58 … +185 °F)
Climate class
Condensation Permitted
Degree of protection in
accordance with EN 60529
IP65, IP68
Degree of protection in
accordance with NEMA 250
NEMA 4X
Electromagnetic Compatibility
Interference emission and
interference immunity
As per EN 61326 and NAMUR NE 21
Medium conditions
Process temperature
Measuring cell with silicon oil
filling
-40 … +100 °C (-40 … +212 °F)
Measuring cell with inert liquid
filling
-20 … +100 °C (-4 … +212 °F)
With extension to Zone 0 -20 … +60 °C (-4 … +140 °F)
Conditions of use for gauge pressure and absolute pressure with flush-mounted diaphragm
Installation conditions
Ambient temperature
Note Observe the temperature class in explosive atmospheres.
Measuring cell with silicon oil
filling
-40 … +85 °C (-40 … +185 °F)
Measuring cell with inert liquid
filling
-20 … +85 °C (-4 … +185 °F)
Measuring cell with Neobee
(FDA-compliant)
-10 … +85 °C (14 … 185 °F)
Display
-30 … +85 °C (-22 … +185 °F)
Storage temperature
-50 … +85 °C (-58 … +185 °F)
(for Neobee: -20 ... + 85 °C (-4 ... +185 °F))
(for high-temperature oil: -10 ... + 85 °C (14 ... 185 °F))
Climate class
Condensation permitted
Degree of protection in
accordance with EN 60 529
IP65, IP68
Degree of protection in
accordance with NEMA 250
NEMA 4X
Electromagnetic compatibility