Factory setting Pt100 (DIN IEC) In three-wire input
Measuring range 0 ... +100 °C (32 ... +212 °F)
Fault current 22.8 mA
Pickup o󹪜set 0 °C (0 °F)
Damping 0.0 s
See also
SITRANS TH100 dimension drawings (Page 221)
12.1.2 Certi󹪝cates and approvals
Only the technical speci󹪝cations listed in the certi󹪝cates (http://www.siemens.com/
processinstrumentation/certi󹪝cates) apply to applications in hazardous atmospheres.
Certi󹪝cates and approvals SITRANS TH100
ATEX (Europe)
DEKRA 21ATEX0033X
DEKRA 21ATEX0034X
Type of explosion protection "Intrinsi‐
cally safe, gas (Ex i IIIC)"
II 1 G Ex ia IIC T6...T4 Ga
II 2 (1) G Ex ib [ia Ga] IIC T6...T4 Gb
II 3 G Ex ic IIC T6...T4 Gc
II 3 G Ex ec IIC T6...T4 Gc
Type of explosion protection "In‐
creased safety (Ex ec)"
II 3 G Ex ec IIC T6...T4 Gc
II 3 G Ex ec[ic] IIC T6...T4 Gc
Type of explosion protection "Intrinsi‐
cally safe, dust (Ex i IIIC)"
II 2 D Ex ia IIIC Db
FM (USA)
FM 3024169
IS Cl I, II, III, Div 1, GP ABCDEFG T4/T5/T6
Cl I, ZN 0 AEx ia IIC T4/T5/T6
NI, S Cl I, II, III, Div 2, GP ABCDFG T4/T5/T6
NI IIC T4/T5/T6
FM (Canada)
FM 3024169C
IS Cl I, II, III, Div 1, GP ABCDEFG T4/T5/T6
Cl I, ZN 0 Ex ia IIC T4/T5/T6
NI, S Cl I, II, III, Div 2, GP ABCDFG T4/T5/T6
NI IIC T4/T5/T6