SITRANS T
Temperature transmitter
SITRANS TH100/TH320/TH420/
TR320/TR420/TF320/TF420 with 4
to 20 mA/HART
Operating Instructions
7NG0.1. / 7NG0.2. (TH/TR320/420 mA/HART)
7NG0.4. (TF320/420 single chamber housing mA/HART)
7NG0.5. (TF320/420 dual chamber housing mA/HART)
7NG3211-0. / 7NG3150-0NN00 (TH100/TH100 slim)
7MF7902-1AD (Display)
7NG3092-8KN (USB modem and SIPROM T)
05/2020
A5E41864807-AB
Getting started
1
Introduction
2
Safety notes
3
Description
4
Installing/mounting
5
Connecting
6
Operating (SITRANS TF)
7
Commissioning
8
Parameter assignment
9
Service and maintenance
10
Diagnostics and
troubleshooting
11
Technical data
12
Dimension drawings
13
Product documentation and
support
A
Remote operation
B
Calibration examples
C
Accessory part sealing
plug / thread adapter
D

Table of Contents

Other manuals for Siemens SITRANS T Series

Questions and Answers

  • A
    Austin LucasAug 20, 2025
    What to do if Siemens SITRANS T failure occurs due to a fault in the field device?
    • K
      Kristina HenryAug 20, 2025
      If the Siemens Transmitter output signal is invalid because of a fault in the field device or peripherals, immediate maintenance is required.
  • K
    kennedyandrewAug 22, 2025
    What to do if Siemens SITRANS T Transmitter failure occurs because the device is out of service?
    • N
      Natasha DuncanAug 22, 2025
      If your Siemens Transmitter output signal doesn't represent the process value because the device mode is set to 'Out of service', you should disable 'Out of service' and enable normal operation.
  • J
    Julian DuranAug 25, 2025
    How to troubleshoot Siemens SITRANS T Transmitter failure due to a hardware configuration error?
    • S
      Susan Scott MDAug 25, 2025
      If the output signal of your Siemens Transmitter is invalid due to parameter setting, a connection error, or a configuration error in the hardware, check the hardware configuration of the device using the HMI or engineering system.
  • C
    carolyn90Aug 26, 2025
    How to resolve loop current saturation in a Siemens SITRANS T Transmitter?
    • M
      Mr. Ronnie White PhDAug 26, 2025
      If the loop current of your Siemens Transmitter has reached its upper or lower saturation limit and can't increase or decrease any further, adjust the loop current scaling.
  • W
    William RoseAug 28, 2025
    What causes Siemens SITRANS T Transmitter to be out of specification and how to fix it?
    • B
      barbara00Aug 28, 2025
      If the Siemens Transmitter detects deviations from permissible ambient or process conditions, indicating an unreliable measured value, check the ambient temperature or process conditions. If possible, install the device at a different location.
  • L
    Logan Sanchez PhDAug 29, 2025
    What to do if Siemens Transmitter loop current is fixed?
    • D
      Diane Wallace MDAug 29, 2025
      If the Siemens Transmitter loop current is being held at a fixed value and isn't responding to process variations, disable the simulation to return to normal operation.
  • G
    Gary Henry IISep 1, 2025
    What does 'Maintenance required' mean on a Siemens SITRANS T Transmitter?
    • A
      Anthony SmithSep 1, 2025
      If your Siemens Transmitter indicates that maintenance is required, plan maintenance of the device because the wear reserve will most likely be exhausted in the next few weeks.
  • A
    April KramerSep 3, 2025
    How to clear a 'Configuration changed' message on a Siemens SITRANS T?
    • B
      Bonnie BentleySep 3, 2025
      If the Siemens Transmitter configuration has changed due to a work process, reset the configuration bit memory to delete the diagnostic message.
  • M
    Megan WilcoxSep 5, 2025
    How to fix an internal RTD sensor error on a Siemens SITRANS T?
    • R
      Richard ThomasSep 5, 2025
      If the Siemens Transmitter detects a sensor error at the internal temperature sensor, reset the device or switch it off and back on.
  • A
    andersoncharlesSep 6, 2025
    What to do if Siemens Transmitter shows electronics temperature alarm?
    • A
      Anita WilliamsSep 7, 2025
      If the Siemens Transmitter indicates that the device is operated outside its specified temperature range, check the operating temperature.

Siemens SITRANS T Series Specifications

General IconGeneral
ModelSITRANS T Series
TypeTemperature Transmitter
Measurement PrincipleResistance variation with temperature (RTD), Voltage generation with temperature difference (Thermocouple)
InputRTD, Thermocouple, Resistance, Millivolt
Input RangeDepends on sensor type (e.g., Pt100: -200°C to +850°C)
Measurement RangeVaries depending on the specific model and sensor type, Corresponds to the input range
Output Signal4 to 20 mA, HART (depending on model)
Accuracy±0.1% of span (typical)
Ambient Temperature-40°C to +85°C (-40°F to +185°F)
Housing materialPlastic or aluminum
Protection ClassIP66, IP67
Sensor TypesRTD (Pt100, Pt200, Pt500, Pt1000, Ni100, Cu10) or TC (Type J, K, N, E, R, S, B, T, C, L)
Communication ProtocolHART

Related product manuals