8.16 Commissioning the USB modem and SIPROM T
8.16.1 Fundamental safety instructions
NOTICE
Improper operating conditions
Device damage.
Only operate the USB modem under laboratory conditions.
Observe the environmental requirements in section Technical data (Page 193).
Only operate the USB modem in a controlled electromagnetic environment. Do not use
radio transmitters, such as mobile phones, in the direct vicinity.
Do not expose the modem to moisture or direct sunlight.
8.16.2 Installing the SIPROM T parameterization software
Requirement
PC with USB port and Windows 10 operating system
Windows Microsoft .NET Framework 4.5 or higher for Windows 10
USB modem present
Procedure
1. Download the SIPROM T parameter assignment software from the Internet free of charge.
(
http://www.siemens.com/processinstrumentation/downloads)
2. Uninstall the SIPROM T installations from your PC.
3. Before you start the installation, read the information for preparation in the Readme 󹪝le.
4. Double-click the "setup.exe" 󹪝le in the SIPROM T software directory.
5. Follow the installation instructions.
6. Download the following USB driver from the Internet: (http://www.ftdichip.com/
Drivers/CDM/CDM20830_Setup.exe)
7. Open the USB driver 󹪝le.
8. Install the downloaded USB driver.
Commissioning
8.16 Commissioning the USB modem and SIPROM T
SITRANS TH100/TH320/TH420/TR320/TR420/TF320/TF420 with 4 to 20 mA/HART
Operating Instructions, 05/2020, A5E41864807-AB 129