Procedure
1. Place the springs on the 󹪝xing screws.
2. Secure the transmitter with the 󹪝xing screws in the connection head cover.
1
2
3
Transmitter Ceramic base of the measuring element
Connection head
Figure 5-3 Securing the transmitter in the connection head cover
5.3 Installing SITRANS TH on DIN rail and G rail
Note
Fixing rings
The 󹪝xing rings included in the scope of delivery for the transmitter are not required for the
installation on DIN rails or G rails.
You can either install the transmitter on a 35 mm DIN rail or on a 32 mm G rail. DIN EN 60715
applies to DIN rails and G rails in this context. The DIN/G rail adapter required for installation can
be ordered as an accessory under the Order No. 7NG3092-8KA.
Adhere to the ambient conditions speci󹪝ed in the technical data.