6.8.4 Closing the device
Procedure
Cover over buttons Cable gland
Cover (front) Cover (back)
Safety catch (front) Safety catch (back)
Figure 6-9 Closing the device
1. Screw on the covers and as far as they will go.
2. Secure both covers with the safety catch or .
3. Close the cover over the buttons.
4. Tighten the screw for the cover over the buttons.
5. Check the tightness of the cable glands in accordance with the degree of protection.
6.9 Connect the Han cable socket to the cable
WARNING
Loss of the safety required for approval by using the Han plug
You may only use the Han plug for non-Ex devices and for devices with intrinsic safety "Ex i";
otherwise, the safety required for the approval is not guaranteed.
Note
Observe the protection class of the Han plug when de󹪝ning the protection class.
The contact parts for the cable socket are supplied.
Connecting
6.9 Connect the Han cable socket to the cable
SITRANS TH100/TH320/TH420/TR320/TR420/TF320/TF420 with 4 to 20 mA/HART
100 Operating Instructions, 05/2020, A5E41864807-AB