Procedure
1. Place the springs on the xing screws.
2. Secure the lock washers.
① Fixing screw M4x35 ② Transmitter
③ Round plate ④ Lock washer DIN 6799 - 3.2 A2
Figure 5-1 Securing the lock washer
3. Secure the transmitter with the xing screws in the connection head base.
① Transmitter
③ Connection head
Figure 5-2 Securing the transmitter in the connection head base
5.2.2 Installing the transmitter in the raised cover of the connection head
Condition
The transmitter is only designed for installation in a type B connection head or larger.
Installing/mounting
5.2 Installing SITRANS TH in a connection head
SITRANS TH100/TH320/TH420/TR320/TR420/TF320/TF420 with 4 to 20 mA/HART