Operating instructions
SITRANS LR560 (PROFIBUS PA)
Radar transmitters
06/2018Edition
SITRANS
www.siemens.com/processautomation

Table of Contents

Other manuals for Siemens SITRANS LR560

Questions and Answers

  • B
    Bryan LopezSep 2, 2025
    What does it mean if sensor is nearing its lifetime limit according to REMINDER 2 on Siemens SITRANS LR560?
    • J
      johnsonjeffreySep 2, 2025
      If the sensor is nearing its lifetime limit according to the value set in REMINDER 2 (DEMANDED) on your Siemens Transmitter, replacement is recommended.
  • R
    Richard FreemanAug 25, 2025
    What to do if calibration interval has expired on Siemens SITRANS LR560?
    • T
      Tina ThomasAug 25, 2025
      If the calibration interval as defined in REMINDER 2 (DEMANDED) has expired on your Siemens Transmitter, perform calibration.
  • A
    Angela StoneSep 23, 2025
    What to do if Siemens Transmitter nearing lifetime limit Reminder 1?
    • R
      ray49Sep 23, 2025
      If your Siemens Transmitter is nearing its lifetime limit according to the value set in Reminder 1, replacement is recommended.
  • R
    Robert MillerSep 7, 2025
    What does it mean when Siemens SITRANS LR560 Transmitter sensor is nearing its lifetime limit according to Maintenance Demanded Limit?
    • A
      Alan ColemanSep 7, 2025
      Replacement of the Siemens Transmitter sensor is recommended as it is nearing its lifetime limit according to the value set in Maintenance Demanded Limit.
  • L
    Linda SanchezSep 13, 2025
    How to fix Siemens Transmitter AIFB values being the same?
    • B
      Brandon HansenSep 13, 2025
      If the INPUT SCALING (2.5.4) (Page 137) upper and lower values for AIFB1 on your Siemens Transmitter are the same, check the configuration for AIFB1 and ensure that the Upper Value and Lower Value (Input Scaling) are not identical.
  • T
    Troy SmithSep 4, 2025
    How to fix invalid user configuration on Siemens SITRANS LR560 Transmitter?
    • S
      Susan HughesSep 4, 2025
      If the user configuration is invalid on your Siemens Transmitter because parameters like Low Calibration Point, High Calibration Point, Volume breakpoints, or Auto False-Echo Suppression are set to invalid values, you should: * Reconfigure the unit. * Ensure that the difference between the High Calibration Point and Low Calibration Point is not less than or equal to zero. Perform a Master Reset if needed.
  • C
    Chad GonzalezAug 30, 2025
    What does it mean if Siemens SITRANS LR560 display shows level or target is out of range?
    • J
      James GreenAug 30, 2025
      If the display shows that the level or target is out of range on your Siemens Transmitter: * Check the specifications. * Check LOW CALIBRATION POINT (2.3.5.1.). * Increase CONFIDENCE (2.4.7.1.).
  • S
    Savannah RiveraSep 15, 2025
    What to do if the controller value is not equal to the displayed value on my Siemens SITRANS LR560 Transmitter?
    • D
      Derek ArnoldSep 16, 2025
      If the controller value isn't matching the displayed value, first, make sure you're checking the correct location in the controller. Then, ensure that scaling is only programmed into the LR560, not the controller itself. Finally, verify that the network connection between the controller and the LR560 is working correctly.
  • T
    tconradSep 10, 2025
    What to do if Siemens SITRANS LR560 reading does not change?
    • C
      cervantesjamieSep 10, 2025
      If the reading on your Siemens Transmitter does not change even when the level does, the device might be processing the wrong echo, such as from a vessel wall or structural member. Try re-locating the device, checking the nozzle for internal burrs or welds, rotating the device 90°, or using AUTO ECHO SUPPRESSION (2.4.8.1.) (Page 132) if necessary.
  • B
    Brian BurkeAug 27, 2025
    How to fix a Siemens SITRANS LR560 Transmitter measurement that is consistently off?
    • L
      lesliethomasAug 27, 2025
      If the measurement from your Siemens Transmitter is consistently off by a constant amount, the issue might be with the calibration settings. Try these solutions: * Check the distance from the sensor reference point to LOW CALIBRATION POINT (2.3.5.1.). * Check the SENSOR OFFSET (2.3.5.3.).

Summary

Safety notes

Description

SITRANS LR560 overview

General description of the 78 GHz FMCW radar level transmitter and its benefits.

Installing;mounting

Basic safety instructions

Safety precautions for hot surfaces, material compatibility, connecting parts, operating pressure, and external stresses.

Connecting

Basic safety information

Safety warnings for unsuitable cables, glands, plugs, hazardous contact voltage, and condensation.

Commissioning

Commissioning via handheld programmer

Using a handheld programmer for device configuration, including key functions, programming, and echo profile.

Operating

Operating via SIMATIC PDM

Using SIMATIC PDM for commissioning and maintaining process devices, including EDD updates.

Parameter Reference

QUICK START (1.)

Overview of wizards for device configuration, filtering echoes, and parameter management.

Service and maintenance

Basic safety notes

General safety notes, emphasizing the device is maintenance-free but requires periodic inspection.

Maintenance and repair work

Safety warnings and procedures for maintenance and repair work, especially in hazardous areas.

Diagnosing and troubleshooting

General fault codes

Table of fault codes, meanings, and corrective actions for troubleshooting.

Operation troubleshooting

Common operating symptoms, their causes, and recommended actions for resolution.

Communication troubleshooting

Troubleshooting steps for communication issues and specific symptoms with corrective actions.

Technical data

Technical reference

Principles of operation

Explains the FMCW radar technology and signal processing for level measurement.

Echo processing

Details on Process Intelligence and Echo selection algorithms.

Loss of Echo (LOE)

Conditions leading to unreliable measurements and fail-safe behavior.

PROFIBUS PA profile structure

Analog Input Function Blocks 1 and 2

Input to AIFB is value with status; outputs PV, SV1, SV2, with quality checks and scaling.

Communications via PROFIBUS PA

SIMATIC PDM

Software package for commissioning and maintaining SITRANS LR560 and other process devices.

Acyclic extended diagnostics (general fault codes)

General fault codes and their corrective actions, including persistence after reset.

HMI menu structure

HMI menu

Detailed listing of the Human Machine Interface menu structure for device configuration.

List of abbreviations

Siemens SITRANS LR560 Specifications

General IconGeneral
TypeRadar Level Transmitter
Frequency80 GHz
Accuracy± 2 mm
Power Supply10.5 to 42 V DC
Protection ClassIP68
Housing MaterialAluminum or Stainless Steel
Beam Angle
ApprovalsATEX, IECEx, FM, CSA, SIL2
Measuring PrincipleFMCW Radar
Output Signal4-20 mA, HART
Communication ProtocolHART
Process Pressure-1 to 40 bar (-14.5 to 580 psi)