What to do if Siemens Transmitter calibration interval has expired?
- CclairepetersenAug 26, 2025
If the calibration interval as defined in Reminder 2 has expired on your Siemens Transmitter, perform calibration.
What to do if Siemens Transmitter calibration interval has expired?
If the calibration interval as defined in Reminder 2 has expired on your Siemens Transmitter, perform calibration.
What to do if Low and High Calibration Points are the same in Siemens Transmitter?
If the Low Calibration Point and High Calibration Point input parameters are the same on your Siemens Transmitter, check the calibration settings of the device and ensure that the settings for the High Calibration Point and Low Calibration Point are different.
What to do if Siemens SITRANS LR560 Transmitter shows material build-up on antenna?
If your Siemens Transmitter display shows material build-up on the antenna, use the air purge feature to clean the antenna or re-locate the device.
What to do if calibration interval defined in REMINDER 1 has expired on Siemens Transmitter?
If the calibration interval as defined in REMINDER 1 (REQUIRED) has expired on your Siemens Transmitter, perform calibration.
What to do if calibration interval has expired on Siemens SITRANS LR560?
If the calibration interval as defined in REMINDER 2 (DEMANDED) has expired on your Siemens Transmitter, perform calibration.
What to do if Fail-safe is activated on Siemens SITRANS LR560?
If Fail-safe is activated on your Siemens Transmitter, it could be due to: * Hardware failure. * Memory failure. * Fail-safe LOE timer expired, possibly due to faulty installation, antenna material buildup, adverse process conditions like foaming, or an invalid calibration range. To address this: * Correct the configuration. * Ensure the installation is correct. * Check for antenna buildup and clean if necessary. * Adjust process conditions to minimize foaming or other adverse conditions. * Correct the calibration range. If the problem continues, or if it's due to hardware or memory failure, contact your local Siemens representative.
What to do when service interval as defined in Maintenance Required Limit has expired on Siemens SITRANS LR560?
Perform service on Siemens Transmitter because the service interval as defined in Maintenance Required Limit has expired.
What does it mean when Siemens SITRANS LR560 Transmitter sensor is nearing its lifetime limit according to Maintenance Demanded Limit?
Replacement of the Siemens Transmitter sensor is recommended as it is nearing its lifetime limit according to the value set in Maintenance Demanded Limit.
What does it mean when Siemens Transmitter sensor is nearing its lifetime limit according to Maintenance Required Limit?
Replacement of the Siemens Transmitter sensor is recommended as it is nearing its lifetime limit according to the value set in Maintenance Required Limit.
What does it mean when Siemens SITRANS LR560 Transmitter is nearing its lifetime limit according to Maintenance Demanded Limit?
Replacement of the Siemens Transmitter is recommended because the device is nearing its lifetime limit according to the value set in Maintenance Demanded Limit.
Type | Radar Level Transmitter |
---|---|
Frequency | 80 GHz |
Accuracy | ± 2 mm |
Power Supply | 10.5 to 42 V DC |
Protection Class | IP68 |
Housing Material | Aluminum or Stainless Steel |
Beam Angle | 3° |
Approvals | ATEX, IECEx, FM, CSA, SIL2 |
Measuring Principle | FMCW Radar |
Output Signal | 4-20 mA, HART |
Communication Protocol | HART |
Process Pressure | -1 to 40 bar (-14.5 to 580 psi) |
General description of the 78 GHz FMCW radar level transmitter and its benefits.
Safety precautions for hot surfaces, material compatibility, connecting parts, operating pressure, and external stresses.
Safety warnings for unsuitable cables, glands, plugs, hazardous contact voltage, and condensation.
Using a handheld programmer for device configuration, including key functions, programming, and echo profile.
Using SIMATIC PDM for commissioning and maintaining process devices, including EDD updates.
Overview of wizards for device configuration, filtering echoes, and parameter management.
General safety notes, emphasizing the device is maintenance-free but requires periodic inspection.
Safety warnings and procedures for maintenance and repair work, especially in hazardous areas.
Table of fault codes, meanings, and corrective actions for troubleshooting.
Common operating symptoms, their causes, and recommended actions for resolution.
Troubleshooting steps for communication issues and specific symptoms with corrective actions.
Explains the FMCW radar technology and signal processing for level measurement.
Details on Process Intelligence and Echo selection algorithms.
Conditions leading to unreliable measurements and fail-safe behavior.
Input to AIFB is value with status; outputs PV, SV1, SV2, with quality checks and scaling.
Software package for commissioning and maintaining SITRANS LR560 and other process devices.
General fault codes and their corrective actions, including persistence after reset.
Detailed listing of the Human Machine Interface menu structure for device configuration.