Application planning
4.6 Protection against explosion
CP-S SA
Operating Instructions, 04/2009, A5E02522341B
17
Three guide elements are sufficient to statically fix a weighing platform or container.
NOTICE
Weighing errors
With four guide elements, there is a risk of the guide elements mutually tensioning, which in
turn induces weighing errors. If you nevertheless want to use four guide elements, the
guide elements must be installed with a sufficient amount of play.
Ensure that the guide elements to be used comply with the principles applicable to weighing
technology.
4.6 Protection against explosion
Protection against explosion
There is no potential risk of ignition from the mounting plates of the load cells. Therefore the
mounting plates are not subject to EC directive 94/9 EC (ATEX).