Architectural Equipment Plan

Equipment Legend

Detailed list of all equipment components with their dimensions, weight, and remarks.

Architectural Notes

Important considerations for installation and site preparation by the customer.

Transport and Delivery Notes

Guidelines for safely moving and delivering the system equipment.

Radiation Scatter Data

Measurements indicating radiation levels at different distances from the system.

Noise Level Specifications

Decibel levels for various system components at specified distances.

Site Readiness Guidelines

Conditions required for successful equipment installation and operation.

Environmental and Power Audit

Siemens offers checks for operating environment post-turnover.

Safety and Service Clearance Plan

Siemens Remote Services (SRS)

Requirements for remote network access for system diagnostics and support.

Safety Clearance Notes

Guidelines for safety distances and potential use of barriers or signs.

Structural Floor Plan

Gantry and Patient Table Mounting Detail

Specifics on how the gantry and table are secured to the floor.

Structural Notes

Key structural considerations and responsibilities for installation.

Floor Loading Information

Weight distribution requirements for the floor structure.

Structural Ceiling Plan

Care Vision Monitor Ceiling Mount Detail

Instructions for mounting the Care Vision monitor to the ceiling.

Medrad Injector Ceiling Mounting Detail

Details for the secure installation of the Medrad injector on the ceiling.

Electrical Raceway Plan

Electrical Legend and Symbols

Explanation of symbols used in electrical diagrams and their meanings.

Electrical Notes

Important guidelines and compliance requirements for electrical work.

Conduit Length Calculations

Guidance on calculating maximum conduit lengths based on site conditions.

Electrical Dimension Plan

Power Schedule and Requirements

Details on voltage, consumption, and breaker requirements for system power.

Grounding Notes

Essential guidelines for proper equipment grounding to ensure safety.

Lighting Guidelines

Recommendations for room lighting for optimal viewing and operation.

Mechanical Plan - Water/Air Split Option

Cooling Diagram and Connections

Schematic showing water flow and connection points for cooling.

Environmental Requirements

Specifications for temperature, humidity, and air quality for optimal operation.

Technical Data for Cooling System

Key performance metrics and specifications for the cooling system.

Outdoor Cooling Unit Mounting Detail

Instructions for securely mounting the outdoor cooling unit.

Mechanical Plan - Hospital Chilled Water Option

Chilled Water Primary Circuit

Details on water flow, pressure, and connections for the primary cooling loop.

Water Flow Rate and Pressure Drop

Graphs and data illustrating water flow and pressure characteristics.

Environmental Requirements for Chilled Water

Climate and air quality specifications for chilled water systems.

Notes for Antifreeze Agent

Guidelines on the use and type of antifreeze for cooling circuits.