Do you have a question about the Siemens SOMATOM Emotion syngo CT 2007E and is the answer not in the manual?
| Type | CT Scanner |
|---|---|
| Model | SOMATOM Emotion syngo CT 2007E |
| Manufacturer | Siemens |
| Year of Release | 2007 |
| Detector Type | Solid-state detector |
| Number of Slices | 16 |
| Slice Count | 16 |
| Scan Time per Rotation | 0.6 - 1.5 s |
| Gantry Aperture | 70 cm |
| Table Weight Limit | 200 kg |
| Display | High-resolution monitor |
| Software | syngo CT 2007E |
| Slice Thickness | 0.6 - 10 mm |
| Rotation Time | 0.6 s |
| Contrast Resolution | 0.3% |
Discusses fundamental safety rules, proper use, and regulations.
Covers personal safety, patient safety, and radiation protection measures.
Details operating conditions, safety equipment, and system modifications.
Addresses patient registration, unique identification, and scan parameters.
Provides an overview of system components and optional equipment.
Describes the gantry's displays, operating elements, and design.
Details patient table characteristics, operating elements, and definitions.
Covers safety advice for monitor, UPS, ECG unit, and connections.
Explains console functions, components, software, and input units.
Describes the use of CDs, DVDs, diskettes, and USB devices.
Lists and describes available system accessories like monitors and special equipment.
Details how to tilt the gantry forward and backward.
Explains table movements, STOP pushbuttons, and manual retraction.
Covers general instructions for using DVD drives, diskettes, and USB devices.
Describes how to use table joystick, scanning footswitch, and monitor supports.
Guides on starting, shutting down, and handling exceptional situations.
Details performing daily function tests for system readiness and safety.
Provides information on patient positioning, standard and optional accessories.
Overviews available positioning aids like head holders, cushions, and straps.
Emphasizes regular maintenance for safety and system integrity.
Lists suitable and unsuitable agents for cleaning and disinfecting.
Provides instructions on cleaning system parts and the mouse.
Explains the importance of regular quality measurements and phantoms.
Details daily checks on water phantom for CT value, pixel noise, and tube voltage.
Covers monthly tests for constancy, including lightmarker, slice thickness, and homogeneity.
Explains the CT Dose Index measurement performed every six months.
Describes using the low contrast phantom section for tests.
Details checking image quality and camera settings through test images.
Ensures monitor image quality and measured values are within defined ranges.
General computation procedure for image reconstruction.
Number quantifying beam attenuation capability of an object.
Calculates dose from CTDIvol and slice width.
Measures accuracy of CT values for a homogeneous object.
Measures spatial resolution via object contrast to image contrast ratio.
Artifact caused by patient movement during scanning.
Object used for functional and quality assurance tests.
Region of interest for quantitative evaluations in CT images.
Period during which radiation is released during a CT scan.
Uninterrupted Power Supply ensures operation during short power failures.