EasyManua.ls Logo

Siemens SXG 75 - To B Connector Problems

Siemens SXG 75
61 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Release 1.1
Technical Documentation
11/2005
TD_Repair_L1-L3_SXG75_R1.1.pdf Page 55 of 61
19 B to B connector Problems
Fault Symptoms
Customer: GRT:
Upper slider keyboard malfunction Keyboard malfunction
Upper slider keypad illumination does not work Current measured failed
Display problems
B to B connector problems
not
oka
y
Watch for oxidation and
damaged pads of the
B to B connector
SCRAP - has to be send
separately to WSC
Check the status of the
B to B connector visually
okay
- check for twisted or
bent contacts
- check for dry joints
Continue with
higher repair level
Exchange
B to B
connector
caused by customer
Back to customer
without repair
okay
not
oka
y
Connector Board to Board
Use hot air blower to remove defective component. Avoid excessive heat! Watch surrounding
components! Resolder new component afterwards.
E-commerce order number: L50634-Z97-C340
E-commerce order name: BOARD TO BOARD 30-POL
Soldering temperature: ~ 360°C TIP Temp.
IRIS Diagnose Code: 32100 Keys / Main / No Function
32200 Keys / Main / Reduced Functionality
36000 Keys / Illumination
Company Confidential
2005©BenQ

Other manuals for Siemens SXG 75

Related product manuals