21 Camera Connector Problems
Fault Symptoms
Customer: GRT:
Camera malfunction Tbd.
Camera connector Problems
Watch for oxidation and
damaged pads of the
camera connector
caused by customer
SCRAP - has to be send
separately to WSC
not
oka
y
okay
Check the status of the
camera connector
visuall
y
Use the resistor test
function of a multimeter
to check connection
between spring
contacts and soldering
contacts.
The value must be ~0
Exchange
camera
connector
Continue with
higher repair level
okay
not
oka
y
not
oka
y
- check for twisted or
bent contacts
- check for dry joints
Back to customer
without repair
Connector CAMERA
Use hot air blower to remove defective component. Avoid excessive heat! Watch surrounding
components! Resolder new component afterwards.
E-commerce order number: L50634-Z97-C379
E-commerce order name: CONNECTOR CAMERA-SOCKET
Soldering temperature: ~ 360°C TIP Temp.
IRIS Diagnose Code: BA000 Accessories / Camera