5.3.4
UMTS TX
The IQ signals from the baseband are directly up-converted to the RF band by a Quadrature
Upconverter and passed to the external filter. The UMTS 1900 TX path is not used in the SXG75.
Blockdiagram RTR6250
VBATT
UMTS2100 TXWCDMA TX
PA_ON0
(level shifted)
Circuit diagram (sheet 4)