20 MMC interface
Reduced size MMC are supported. The card interface is supplied from VREG_AUX1 (2.85V). Card
insertion is detected by the MMC_CD line. This line is an input to a MSM6250 port. The line has an
external pull-up (R1400) to VREG_MSME. When a card is inserted, the MMC_CD line is pulled to
ground by an internal connection in the card. This causes an interrupt to be generated to the
MSM6250.
The MMC interface lines are MMC_DATA, MMC_CLK, and MMC_CMD. These lines are connected
directly to MSM6250 ports. Note that MMC_DATA and MMC_CMD ports on the MSM6250 are 3
volt-tolerant.
The MMC clock is programmable by the MSM6250 and is set to 9.6 MHz (maximum possible
operating frequency, when the MMC clock is derived from the 19.2MHz VCTXO).