5.2 List of jointly supported AT-commands
AT-commands listed in the tables below are supported by both TC35i and TC35. Command
defaults, however, may differ.
NOTE: Many commands are available only after the PIN has been entered. For a full list, please refer to
respective AT reference manuals.
5.2.1 Standard V.25ter AT Commands
Table 5-1: Standard V.25ter AT commands
# AT Command
1 A/ Repeat previous command line
2 +++ Switch from data mode to command mode
3 AT\Qn Flow control
Differing implementation
TC35i
AT\Qn included within user profile. See comments under AT&W.
TC35
-
4 ATA Answer a call
5 ATD Mobile originated call to dial a number
Differing implementation
TC35i
International calls to be dialled exclusively starting with "+", i.e. "00" at the beginning of a
dialling string will not be translated into a "+".
TC35
-
6 ATD><mem><n> Originate call to phone number <n> in memory <mem>
7 ATD><n> Originate call to phone number selected from active memory
8 ATD><str> Originate call to phone number in memory with corresponding field
9 ATDI Mobile originated call to dialable ISDN number <n>
10 ATDL Redial last telephone number used
11 ATE Enable command echo
Differing parameters
TC35i
MUX: Echo is disabled at the start of MUX mode and
is not available on logical channels, ATE1 responds
with ERROR
TC35
MUX: Echo is available on logical channels and is
initially enabled only on main (data) MUX channel.
12 ATH Disconnect existing connection
13 ATI Display product identification information
14 ATI[value] Display additional identification information
15 ATL Set monitor speaker loudness
16 ATM Set monitor speaker mode
17 ATO Switch from command mode to data mod
18 ATQ Set result code presentation mode
19 ATP Select pulse dialling
20 ATS0 Set number of rings before automatically answering the call
Differing implementation
TC35i
ATS0 applies to incoming voice calls as well.
TC35
ATS0 applies only to incoming data or fax calls.
22 ATS2 Escape code sequence
23 ATS3 Write command line termination character
24 ATS4 Set response formatting character
25 ATS5 Write command line editing character
26 ATS6 Set pause before blind dialling
27 ATS7 Set number of seconds to wait for connection completion
Differing implementation
TC35i
ATS7 applies to voice calls as well.
TC35
ATS7 applies only to data calls.
28 ATS8 Set number of seconds to wait for comma dial modifier
29 ATS10 Set disconnect delay after indicating the absence of data carrier
30 ATS18 Extended error report
31 ATT Select tone dialling

Table of Contents

Other manuals for Siemens TC35i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens TC35i and is the answer not in the manual?

Siemens TC35i Specifications

General IconGeneral
BrandSiemens
ModelTC35i
CategoryModem
LanguageEnglish

Related product manuals