6 - USE
Parameter Description
Access
level
Adjustment
range
Default value
Custom
value
CH modules state State of the heat generators used for the heating service
Installer
Actual setpoint Actual setpoint of the heat generators
Installer Value Value
Water heater t. General cascade temperature
Installer Value Value
Phase N/A
Installer Value Value
Light-on delay Light-on delay time
Installer Value Value
Light-off delay Light-off delay time
Installer Value Value
Modulation delay Delay time to modulation of the heat generators setpoint
Installer Value Value
1 (Heating/DHW) Module1 service (DHW/Heating)
Installer Value Value
2 (Heating/DHW) Module 2 service (DHW/Heating)
Installer Value Value
3 (Heating/DHW) Module 3 service (DHW/Heating)
Installer Value Value
4 (Heating/DHW) Module 4 service (DHW/Heating)
Installer Value Value
1 Standby/Active 1 % Module 1 (Standby/Active) and percentage of 0-10V signal
Installer Value Value
2 Standby/Active 1 % Module 2 (Standby/Active) and percentage of 0-10V signal
Installer Value Value
3 Standby/Active 1 % Module 3 (Standby/Active) and percentage of 0-10V signal
Installer Value Value
4 Standby/Active 1 % Module 4 (Standby/Active) and percentage of 0-10V signal
Installer Value Value
Alarm output Alarm contact status
Installer ON...OFF
DHW modules state State of the heat generators used for the DHW service
Installer
Light-on delay Light-on delay time
Installer Value Value
Light-off delay Light-off delay time
Installer Value Value
DHW tank sens Hot water tank temperature
Installer Value Value
Actual setpoint Actual setpoint of the hot water tank
Installer Value Value
Type State Cmd Temp
1 Heat/DHW off 0.0%
2 Heat/DHW off 0.0%
3 Heat/DHW off 0.0%
4 Heat/DHW off 0.0%
Service, state and percentage of the 0-10V signal of each heat generator used for the DHW service
Installer
Antileg counter days Counter for the days when the hot water tank is below the Anti-legionella temperature
Installer Value Value
Antileg cycle Counter Antilegionella cycle counter
Installer Value Value
Tank pump Tank pump state
Installer Value Value
Shufe pump Shufe pump state
Installer Value Value
DHW return pump DHW return pump state
Installer Value Value
DHW return sensor Temperatur measured by DHW return sensor
Installer Value Value
DHW return setp Setpoint of DHW return sensor
Installer Value Value
Modules state State of the heat generators – used for heating or for DHW
Installer
Module 1 Service supplied by heat generator 1
Installer Value Value
Module 2 Service supplied by heat generator 2
Installer Value Value
Module 3 Service supplied by heat generator 3
Installer Value Value