- 16 -
3. Technical Specification of PERIDECT+
3.1. CUP+ Control Unit PERIDECT+
Supply voltage: 9 – 16 VDC
Consumption: 160 mA
Operational temperature range: -40°C to +80°C
Inputs: 1x tamper contact
Outputs: 4x open collector type
Protection: IP20
Dimensions: 150 x 100 x 40 mm
3.2. LCP+ Line Controller PERIDECT+
Supply voltage: 9 – 16 VDC
Consumption: 60 mA (350 mA at full DSP+ capacity)
Default line voltage: 24V (36V when on or exceeding 1,5km of detection line)
Operational temperature range: -40°C to +85°C
Protection: IP20
Dimensions: 150 x 100 x 40 mm
3.3. LIP+ Line Input PERIDECT+
Power supply: powered by the line controller bus
Consumption: 2 mA max.
Operational temperature range: -40°C to +85°C
Inputs: 2x double-balanced (balancing resistors of 2 x 1k2 and 2 x 3k3)
Electronic elements protection: IP65
Dimensions: 50 x 30 x 20 mm (outer casing 110 x 110 x 40 mm)
3.4. DSP+ Detection Sensor PERIDECT+
Power supply: powered by the line controller bus
Consumption: 2 mA max.
Operational temperature range: -40°C to +85°C
Electronic elements protection: IP65
Dimensions: 50 x 30 x 20 mm (outer casing 110 x 110 x 40 mm)
3.5. LSP+ Line Separator PERIDECT+
Power supply: powered by the line controller bus
Consumption: typically 1 mA
Operational temperature range: -40°C to +85°C
Electronic elements protection: IP65
Dimensions: 50 x 30 x 20 mm (outer casing 110 x 110 x 40 mm)