EasyManuals Logo

Sigineer Power M6048D User Manual

Sigineer Power M6048D
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
www.sigineer.com
4
WITH LIFE SUPPORT SYSTEMS OR OTHER MEDICAL EQUIPMENT OR DEVICES. WE MAKE NO
WARRANTY OR REPRESENTATION IN CONNECTION WITH THEIR PRODUCTS FOR SUCH
USES. USING THE INVERTER/CHARGER WITH THESE PARTICULAR EQUIPMENTS IS AT YOUR
OWN RISK.
1.2 Precautions When Working with Batteries
1.2.1 If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters eye,
immediately flood eye with running cold water for at least 20 minutes and seek medical attention
immediately.
1.2.2 Never smoke or allow an open spark or flame in the vicinity of battery or engine. When batteries are
being recharged, they generate hydrogen gas that is explosive in certain concentrations in air (explosive
limits are 4.1 to 72 percent hydrogen in air). The ventilation system can exchange an adequate amount of
fresh air for the number of batteries being charged. This is essential to prevent an explosion.
1.2.3 Do not allow metal objects to contact the battery terminals. The resulting spark or short-circuit on the
battery of other electrical part may cause an explosion.
1.2.4. Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a
lead-acid battery. A lead-acid battery produces a short-circuit current high enough to weld a ring or the like
to metal, causing a severe burn.
1.2.5 To reduce the risk of injury, charge only rechargeable batteries suitable for use by this inverter such as
deep-cycle lead acid, lead antimony, lead calcium gel cell, absorbed mat, NiCad/NiFe or Lithium battery.
Other types of batteries may burst, causing personal injury and damage. NEVER charge a frozen battery.
See battery type of this manual for more information about acceptable battery types and program settings.
1.2.6 Don’t install the inverter near batteries, the inverter may heat battery electrolyte and cause corrosive
fumes to vent and damage/corrode nearby electronics or metals.
1.3 Target Group
This document is intended for qualified persons and end users. Tasks that do not require any particular
qualification can also be performed by end users. Qualified persons must have the following skills:
Knowledge of how an inverter works and is operated
Training in how to deal with the dangers and risks associated with installing and using electrical
devices and installations
Training in the installation and commissioning of electrical devices and installations
Knowledge of the applicable standards and directives
Knowledge of and compliance with this document and all safety information
2 Introduction
2.1 General Information
Thank you for purchasing the M series Off Grid Solar Inverter/Charger.
The M Series Transformer Based Off Grid Solar Inverter/Charger is a combination of 4 products:
1. Transformer based DC to AC power inverter
2. AC to DC battery charger

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sigineer Power M6048D and is the answer not in the manual?

Sigineer Power M6048D Specifications

General IconGeneral
BrandSigineer Power
ModelM6048D
CategoryInverter
LanguageEnglish

Related product manuals