SL-50 SL-60 MIXERS
13 of 23
CLEANING AND MAINTENANCE OPERATIONS.
DO NOT CARRY OUT ANY MAINTENANCE OR CLEANING WITH ELECTRICITY
CONNECTED
The mixer does not require particular maintenance operations. All bearings and
transmission parts are lubricated for life. Keep the mixer clean to avoid flour from
depositing in the moving organs thus generating bothersome creaking and abnormal
wear.
To tension the belt,
remove the upper
casings, loosen the
motor bolts and act on
the appropriate register.
Fasten the motor bolts,
place the casings back
and test the machine.
Anomalies of the grid
micro: remove the
upper protection
casing, intervene on
the micro, close the
casing again and test
the machine.
Should a power cable
be damaged, replace
it with a H07RN/F
cable with a 3x1.5
mm
2
section
Cleaning: the mixer is not jet-
proof. Do not wash it with
running water. Clean it with a
moist cloth and neutral
detergents, such as
degreasing agents based on
Castile soap
A
EXTRAORDINARY MAINTENANCE:
To carry out interventions not specially mentioned in the manual, refer
to personnel authorised by SIGMA SrL. To replace the motor or the
circuit boards, or else if the mixer falls, contact our assistance service
for an intervention on site or else an overhaul at the factory
To tension the chain
and the lower bowl
dragging chain remove
the lower casing (tilt
the machine) and act
on the appropriate
registers. Replace the
casing and test the
machine
Electric interventions:
they must be carried
out by qualified
electrician, with
reference to the
layouts attached at the
end of the manual

Related product manuals